Typical drive system diagrams – Rockwell Automation 2099-BMxx Kinetix 7000 High Power Servo Drive User Manual User Manual

Page 13

Advertising
background image

Rockwell Automation Publication 2099-UM001D-EN-P - December 2012

13

Start

Chapter 1

Typical Drive System
Diagrams

Typical Kinetix 7000 system installations include three-phase AC configurations,
with and without the line interface module (LIM), and DC common bus
configurations.

Figure 1 - Kinetix 7000 System Configuration with LIM and External Resistive Shunt

MAIN VAC

MAIN VAC

24V DC
Control Power

External Shunt Module (optional component). See

External Shunt Modules on

page 156

for more

information.

2090-XXLF-TCxxxx

AC Line Filter

2094-BL75S

Line Interface Module

(optional component)

460V AC

Three-Phase

Input Power

RSLogix 5000 Software

Input

Logix 5000 Controller

Output

1756-MxxSE SERCOS
Interface Module

2090-SCxxx-x

SERCOS Fiber-Optic Ring

Commissioning

2099-BMxx-S Kinetix 7000 Drive

HPK-Series Motors, RDD-Series Direct Drive Motors, MPM-
B165xx and MPM-B215xx, and MPL-B5xxx, MPL-B6xxx,
MPL-B8xxx, and MPL-B9xxx (shown) Servo Motors

ControlLogix Chassis

Motor Power Cable

Encoder
Feedback
Cable

2090-K6CK-Dxxx
Low Profile Connector Kits for
I/O, Motor Feedback,
and Auxiliary Feedback

Safe-off,

General Purpose I/O,

General Purpose Relay

Connections

Advertising