Configure and Startup the Kinetix 7000 Drive System

Chapter 5

Your new module appears under the I/O Configuration folder in the
Controller Organizer and the Module Properties dialog box opens.

6. Click the SERCOS Interface tab and reference the table below.

7. Verify that the Data Rate setting matches DIP switches 2 and 3

(communication rate) as set on the drive, or use the Auto Detect setting.

8. From the Cycle Time pull-down menu, choose the Cycle Time according

to the following table.

9. Verify that the Transmit Power setting (high) matches the Optical Power

DIP switch 1 as set on the drive.

10. Enter the Transition to Phase setting.

The Transition to Phase default setting is 4 (phase 4). The Transition to
Phase setting stops the ring in the phase specified.

11. Click OK.
12. Repeat steps 1...11 for each SERCOS module.

Logix SERCOS Module

Number of Axes

Data Rate

1756-M03SE or
1756-L60M03SE

Up to 3

4 or 8 Mbps

1756-M08SE

Up to 8

1756-M16SE or
1784-PM16SE

Up to 16

1768-M04SE

Up to 4

Data Rate

Number of Axes

Cycle Time

4 Mbps

Up to 2

0.5 ms

Up to 4

1 ms

Up to 8

2 ms

No support for axes 9...16

8 Mbps

Up to 4

0.5 ms

Up to 8

1 ms

Up to 16

2 ms

TIP

The number of axes/module is limited to the number of axes as
shown in

step 6

.