Chapter 3

Kinetix 7000 Connector Data

Analog Inputs (IOD Connector)

Two analog inputs are provided, with 14-bit resolution (13 data bits, plus sign).
The analog data streamed to RSLogix by these inputs is useful for managing
dynamic machine operations, for example tension transducers in an outer tension
control loop.

The input range of these inputs is ±10V, and overvoltage protection is ±12V.
Inputs are updated at the drive every 125 μs. Frequency response of the input is
up to 4 kHz, and input impedance is 12 k

Ω

.

Analog inputs are available as a real time attribute and Get System Value (GSV)
within RSLogix software.

The schematic below depicts the Analog Input circuits. It is provided as a
reference only.

Figure 37 - Analog Input Circuit Diagram

IMPORTANT

RSLogix 5000 software, version 15, does not support analog input
utilization.

ATTENTION: Gain and offset attributes are not provided for the Analog Inputs
input signals, and no drive faults are issued.

0.1

μ

F

0.1

μ

F

IOD-19

IOD-20

+

V+

V–

100

Ω

IOD-21

IOD-22

+

V+

V–

100

Ω

0.1

μ

F

0.1

μ

F

Analog_Input_1_Ret

Kinetix 7000 Drive

Customer-supplied

Input Device

Anlg In 1

Anlg In 2

Sense

Out

Ref

Analog_Input_1

Analog_Input_2_Ret

Analog_Input_2

Sense

Out

Ref