Wire AC Input Power

Wire 460V AC input power to your Kinetix 7000 drive as described in

Table 35

.

See Power Terminal Block (PTB) Connections for more information.

Table 35 - AC Input Power Connections

Wire DC Input Power (Common Bus Configurations Only)

Wire the DC input power from a leader regenerative power supply (8720MC-
RPS) to a Kinetix 7000 drive as described in

Table 36

. See Power Terminal Block

(PTB) Connections on page

51

for more information.

Kinetix 7000
Drive Cat. No.

Signal

Terminal

Recommended Wire Size
mm

2

(AWG)

Torque
N

m (lb

in)

2099-BM06-S
2099-BM07-S
2099-BM08-S

L1
L2
L3
Ground

R
S
T
PE

25…2.5 (3…14)

1.8 (16)

2099-BM09-S

L1
L2
L3

R
S
T

50…4 (1/0…12)

3.6 (32)

Ground

PE

50…4 (1/0…12)

5 (44)

2099-BM10-S

L1
L2
L3

R
S
T

70…10 (2/0…8)

15 (133)

Ground

PE

50…4 (1/0…12)

5 (44)

2099-BM11-S
2099-BM12-S

L1
L2
L3

R
S
T

100…10 (4/0…8)

12 (104)

Ground

PE

50…4 (1/0…12)

5 (44)

IMPORTANT

DC power from the regenerative power supply (8720MC-RPS) is typically
routed to a power distribution box. Fusing will be placed before and after
the distribution box, providing protection for both the 8720MC-RPS and
Kinetix 7000 drive.