This section describes how to query, add, modify, and remove alarm indexes, and how to configure

monitor indexes to use global thresholds or custom thresholds in reports.

Viewing the global threshold List

1.

Click the Resource tab.

2.

Select Application Manager > Configurations from the navigation tree.
The Configurations page appears.

3.

Click Threshold Configuration.
The global threshold list displays all monitor indexes enabled with the threshold alarm function
and the global threshold of each index.

4.

Click an application category to view monitor indexes for this application category.
The Application Type field also refreshes.
To view baseline configurations for all application categories, click Unlimited next to Application
Category.

5.

Click an application type to view monitor indexes for this application type.
To view baseline configurations for all application types of an application category, click the
application category and click Unlimited next to Application Type.
Global threshold list contents

{

Application Type—Type of the application.

{

Application Unit—Name of the application unit to which the monitor index belongs. Each
application unit corresponds to an independent area in the application monitor report.

{

Index—Name of the application monitor index enabled with the threshold alarm function.

{

Threshold Condition—Threshold condition, which can be Greater than or equal to (≥), Less
than or equal to (≤), Include, or Exclude.

{

Enable Level-1 Threshold—Displays whether the Level-1 threshold for the monitor index has
been set.

{

Level-1 Threshold—Level-1 threshold value of the monitor index.

{

Trigger Times—Number of times that the monitor index meets the Level-1 threshold to trigger an
alarm.

{

Enable Level-2 Threshold—Displays whether the Level-2 threshold for the monitor index has
been set.

{

Level-2 Threshold—Level-2 threshold value of the monitor index.

{

Trigger Times—Number of times that the monitor index meets the Level-2 threshold to trigger an

alarm.

{

Modify—Click the Modify icon

to modify the predefined or user-defined global threshold

values.

{

Delete—Click the Delete icon

to delete the predefined or user-defined global threshold

values.

6.

Click Refresh to refresh the global threshold list.

7.