Automating a show – Leprecon LP-X24 Manual v3.2 User Manual

Page 114

Advertising
background image

110

Chapter Five

Advanced Programming and Editing Techniques

LP-X24 and LP-X48 Users Manual

Overwrite existing.

There is an existing scene list on the

destination playback. Do you want to

Yes / No

overwrite?

Press

the

Yes key to overwrite the information. Press the No/Esc key to cancel the

operation.

Automating a Show

After you have recorded a series of looks to a playback, you run the show by pressing
the playback's Select button at the appropriate times to move from one look to the next.

In many cases, it may be desirable to automate the show. For example, you may design
the lighting for a product display. The lighting consists of ten different looks and the
series of looks repeats every two minutes. This involves setting timings for each look.

Automation Terminology

Timing values consist of three elements: Hold Time, Fade Time and Start Delay.
Hold Time is the total time of the lookthat is, the total time until the subsequent

look will begin. For scene lists that you intend to advance manually, the Hold Time is
set to Infinite. For scene lists that you intend to run automatically, the Hold Time is
set for each look and must be less than Infinite.

Start Delay is the duration from the start of a look until a property of the light

responds. For example, you might want to change the beam at the beginning of the
look and delay the color change by three seconds. You would set a three-second
Start Delay on the Color property.

Fade Time is the duration during which the intensity of the light will change from the

current level to the new level. The Fade Time starts at the end of the start delay.

Advertising
This manual is related to the following products: