PROFIsafe on board

Appendix

Consistent parameter data

6

103

EDSLCMX3024-SPS EN 5.0

Configuring consistent data
Consistency is achieved by an appropriate PROFIBUS master configuration. Please refer to

the corresponding instructions for your configuring software for this purpose.

Tip!

Consistency configuration depends on the PROFIBUS master configuring

software. When using a Siemens-S5 PLC, please consider:

ƒ

Consistency is switched on by any word in the consistent area

ƒ

Consistency must be switched off by a specific switch-off word.

ƒ

The type of CPU, consistency and address area determines which word

switches off consistency.