Commissioning

Preconditions

The E82ZBB diagnosis terminal

8

139

EDSLCMX3024-SPS EN 5.0

Altering parameters in the menus

Step

Key

sequence

Display

Comment

Example

1.

Inhibit

motor

starter



Only required if you want to change codes

which are marked with  in the code table,

e. g. C0002

All other parameters can be altered during

operation.

2.

Set

parameters



Increase C0012

(acceleration

time) from

0.50 s to 1.00 s

3.

XXXX

Select code

0012

4.


001

For codes without subcodes: skip to 

(continue with 6.)

5.



xxx

Select subcode

6.

0.50

s

7.



XXXXX

Set parameter

1.00

s

8.

STOre

Confirm entry when is blinking

Confirm entry when is not blinking; is

inactive

9.

Start ”loop” at 2. again to set further

parameters