Commissioning
Preconditions
The E82ZBB diagnosis terminal
8
139
EDSLCMX3024-SPS EN 5.0
Altering parameters in the menus
Step
Key
sequence
Display
Comment
Example
1.
Inhibit
motor
starter
Only required if you want to change codes
which are marked with in the code table,
e. g. C0002
All other parameters can be altered during
operation.
2.
Set
parameters
Increase C0012
(acceleration
time) from
0.50 s to 1.00 s
3.
XXXX
Select code
0012
4.
001
For codes without subcodes: skip to
(continue with 6.)
5.
xxx
Select subcode
6.
0.50
s
7.
XXXXX
Set parameter
1.00
s
8.
STOre
Confirm entry when is blinking
Confirm entry when is not blinking; is
inactive
9.
Start ”loop” at 2. again to set further
parameters