Code table

8

151

EDSLCMX3024-SPS EN 5.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.
C0409

Logic linking of

digital input signals

Code is individually adjustable in

four parameter sets.

1 E1

0

0

Not linked

1

E1 AND E4

2

E1 OR E4

2 E2

0

0

Not linked

1

E2 AND E4

2

E2 OR E4

3 E3

0

0

Not linked

1

E3 AND E4

2

E3 OR E4

4 E4

0

0

Not linked

1

E4 AND E3

2

E4 OR E3