Technical data – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual

Page 18

Advertising
background image

Technical data

Rated data

3

18

EDSLCMX3024-SPS EN 5.0

Note!

The motor starters are designed for rated currents between 1 A and 7 A.
If motors with rated currents < 1 A are operated on the motor starters, please

observe the following:

ƒ

The internal I

2

xt monitoring cannot be used because of the low current.

– Switch off the internal I

2

xt monitoring (C0121 = 0).

– Use a PTC or thermal contact (NC contact) to monitor the motor

temperature

– Appropriate external motor protection switches can be used in addition.

ƒ

The mains phase failure control can respond during operation, although no

main failure has occurred.

– Deactivate the mains phase failure control (C0122 = 3) to ensure that the

drive will not switch off with an error message.