Profisafe on board, Code table communication-relevant lenze codes, C1510: configuration of process input data – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual

Page 87

Advertising
background image

PROFIsafe on board

Code table

Communication-relevant Lenze codes

6

87

EDSLCMX3024-SPS EN 5.0

C1510:

Configuration of process input data

Code

Subcode

Index

Possible settings

Data type

Lenze

Selection

C1510

23065

d

=

5A19

h

1

1 ... 16

FIX32

1 (PIW1)

see table below

2 (PIW2)
3 (PIW3)
4 (PIW 4)
5 (PIW 5)
6 (PIW 6)
7 (PIW 7)
8 (PIW 8)
9 (PIW 9)
10 (PIW 10)

Bit status information or actual values of the controller can be assigned freely to the max.

10 process data input words (PIW) of the master.

Selection

Scaling

1

FIF status word 1 (FIF-STAT1)

16 bits

2

FIF status word 2 (FIF-STAT2)

16 bits

3

Reserved

4

Reserved

5

Apparent current of motor 1 (MCTRL1-IMOT1)

100

dec

1 A

6

Apparent current of motor 2 (MCTRL1-IMOT2)

7

Apparent current of motor 1 or motor 2

(MCTRL1-I MOT1/2)

Preselection via C0410/15

8

LCU error code

9

Reserved

10

Reserved

11

Reserved

12

Reserved

13

FIF-OUT.W1

14

FIF-OUT.W2

15

Reserved

16

Reserved

Advertising