Profisafe on board, Code table communication-relevant lenze codes, C1510: configuration of process input data – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual
Page 87
![background image](/manuals/566239/87/background.png)
PROFIsafe on board
Code table
Communication-relevant Lenze codes
6
87
EDSLCMX3024-SPS EN 5.0
C1510:
Configuration of process input data
Code
Subcode
Index
Possible settings
Data type
Lenze
Selection
C1510
23065
d
=
5A19
h
1
1 ... 16
FIX32
1 (PIW1)
see table below
2 (PIW2)
3 (PIW3)
4 (PIW 4)
5 (PIW 5)
6 (PIW 6)
7 (PIW 7)
8 (PIW 8)
9 (PIW 9)
10 (PIW 10)
Bit status information or actual values of the controller can be assigned freely to the max.
10 process data input words (PIW) of the master.
Selection
Scaling
1
FIF status word 1 (FIF-STAT1)
16 bits
2
FIF status word 2 (FIF-STAT2)
16 bits
3
Reserved
4
Reserved
5
Apparent current of motor 1 (MCTRL1-IMOT1)
100
dec
≡
1 A
6
Apparent current of motor 2 (MCTRL1-IMOT2)
7
Apparent current of motor 1 or motor 2
(MCTRL1-I MOT1/2)
Preselection via C0410/15
8
LCU error code
9
Reserved
10
Reserved
11
Reserved
12
Reserved
13
FIF-OUT.W1
14
FIF-OUT.W2
15
Reserved
16
Reserved