Electrical installation
Motor connection
ELCAMWIxxx4SNNPSNN motor starter
5
28
EDSLCMX3024-SPS EN 5.0
5.4
Motor connection
5.4.1
ELCAMWIxxx4SNNPSNN motor starter
lcu121_000d
X21 - Motor 1 connection
Pin
Connection
Description
Data
Connector: Socket, Harting HAN-Modular
a1
U1
Phase U1
Output voltage = mains voltage
Max. continuous output current
dependent on type
(sum of all output currents)
a2
V1
Phase V1
a3
W1
Phase W1
c1
+PTC
Motor temperature monitoring
PTC thermistor (PTC) or thermal contact
(NC contact)
c2
~
Brake rectifier supply voltage
The brake rectifier is installed in the motor
terminal box
c3
~
c4
S1
Switch for disconnection on the DC side
c5
S2
c6
-PTC
Motor temperature monitoring
PTC thermistor (PTC) or thermal contact
(NC contact)
PE
PE conductor