Commissioning, Code table – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual
Page 150
Commissioning
Code table
8
150
EDSLCMX3024-SPS EN 5.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0170
TRIP reset
configuration
0
0
TRIP reset by switching the 24 VDC supply
voltage, ”OFF-ON” service switch, via
PROFIBUS or by means of the
key
z
TRIP reset via PROFIBUS with
C0043, C0410/12 or C0135
bit 11
z
Auto TRIP reset resets all
faults automatically after the
time in C0171 has expired
1
As 0 and additionally auto TRIP reset
2
TRIP reset by switching the 24 VDC supply
voltage or via bus function module
3
TRIP reset by switching the 24 VDC supply
voltage
C0171
Deceleration for
auto TRIP reset
0.00
0.00
{0.01 s}
60.00
C0178
Operating hours
{h}
Read only
Total time of service
switch = ”ON”
C0179
Mains operating
hours
{h}
Read only
Total time of mains on
C0200
Software
identification code
82S8215V_xyz00
Read only on the PC
x = main version
y = lower version
C0201
Software creation
date
Read only on the PC
C0202
Software
identification code
Output in the diagnosis terminal as a string in 4
parts with 4 characters each
Diagnosis terminal read only
x = main version
y = lower version
1
82S8
2
215V
3
_xyz
4
00
C0304
Service codes
Changes by Lenze service only!
...
C0310
C0370
Service code
Changes by Lenze service only!
C0372
Function module
identification
6
PROFIBUS-DP
Read only
10
No valid recognition
C0408
Minimum
operating time
0.00
{0.01 s}
20.00
z
C0408 can be set differently
in the four parameter sets.
z
After a LOW-HIGH edge at Ex,
the digital signal linked with
Ex is active for at least the
time set.
z
Each LOW-HIGH edge during
a running cycle resets the
time.
1 E1
0.00
start043
S (Ex)
S (Ex)
S (Ex)
Ex
Ex
Ex
t
C0408
C0408
2 E2
0.00
Ex:
level on E1 or E2
S (Ex):
digital signal linked to E1 or E2