Commissioning

Code table

8

146

EDSLCMX3024-SPS EN 5.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.
C0002

uSEr

(Cont.)

Saving own setting

9

PAR1 Ö Own setting

You can store your own setting

for the parameters of the

standard device (e.g. delivery

condition of your machine):

1. Check that parameter set 1 is

active

2. Inhibit controller

3. Set C0003 = 3, confirm with

4. Set C0002 = 9, confirm with

, your own setting is

stored

5. Set C0003 = 1, confirm with

6. Enable controller

Loading/copying

own setting

5

Own setting ÖPAR1

Restore your own setting in the

selected parameter set

6

Own setting ÖPAR2

7

Own setting ÖPAR3

8

Own setting ÖPAR4

10 ... 14 Without function
20

Without function

C0003

Saving parameters

non-volatilely

1

0

Do not save parameters in the EEPROM

Data loss after mains

disconnection

1

Always save parameters in the EEPROM

z

Active after every mains

connection

z

Cyclical altering of

parameters via bus module is

not permitted

3

Save own setting in the EEPROM

Afterwards save parameter set 1

via C0002 = 9 as your own

setting

C0004

Bar graph display

54

1

{code no.}

989

z

After mains connection, the

bar graph display shows the

selected value in %

z

Range -180 % ... +180 %

54

Apparent current of motor 1 (C0054)

C0005

Fixed input signal

configuration

0

Code is individually adjustable in

four parameter sets

0

All digital input signals arrive from the

connections X41 and X42

Sets C0410/x = Lenze setting

200

The digital control signals arrive from the

PROFIBUS with a fixed assignment

Sets C0410/x = 200

255

Freely configurable mixed mode: the

digital control signals arrive from the

connections X41/X42 and from the

PROFIBUS

C0410/x has been freely

configured

C0006

uSEr

LCD display

language

0

0

English

1

German

2

Spanish

C0012
uSEr

Acceleration time

0.00

{0.01 s}

3.00 Time for the change in voltage

U

0

... U

mains

1 Motor 1

0.50

2 Motor 2

0.50

C0013

Deceleration time

0.00

{0.01 s}

3.00 Time for the change in voltage

U

mains

... 0 V

1 Motor 1

0.50

2 Motor 2

0.50