Profisafe on board – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual
Page 97
Advertising
![background image](/manuals/566239/97/background.png)
PROFIsafe on board
Code table
Diagnostics
6
97
EDSLCMX3024-SPS EN 5.0
C1523:
Display of all process data words from the motor starter
Code
Subcode
Index
Possible settings
Data type
Lenze
Selection
C1523
1...16
23052
d
=
5A0C
h
0
[1]
65535 U16
Display of the process data words 1 ... 16 transferred from the motor starter to the
”PROFIsafe on board”:
Subcode
Process data word
1 FIF status word 1 (FIF-STAT1)
2 FIF status word 2 (FIF-STAT2)
3 Reserved
4 Reserved
5 Apparent current of motor 1 (MCTRL1-IMOT1)
6 Apparent current of motor 2 (MCTRL1-IMOT2)
7 Apparent current of motor 1 or motor 2 (MCTRL1-IMOT1/2)
8 LCU motor starter error code
9 Reserved
10 Reserved
11 Reserved
12 Reserved
13 FIF-OUT.W1
14 FIF-OUT.W2
15 Reserved
16 Reserved
Advertising