Electrical installation – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual

Page 35

Advertising
background image

Electrical installation

Control terminals

5

35

EDSLCMX3024-SPS EN 5.0

Digital outputs

Note!

If inductive loads are being connected, it is essential to use a spark suppressor

at the digital output.

X45 - Digital outputs O1, O2
Pin

Signal

Description

Data
Connector: Socket, 4-pin, M12

1

+24 V

Supply

2

Signal 1

O1

HIGH

U

DC

at X11

3

GND

Reference potential

LOW

0 ... +4 V

4

Signal 2

O2

Max. 500 mA

Diagnostic interface

X70 - Diagnostic interface
Pin

Signal

Description

Data

1 ... 4

Connection for handheld keypad or PC

interface

Connector: Plug connector, 4-pin

Connection only possible using a Lenze

system cable E82ZWLxxx

Only use PC interfaces featuring electrical

isolation:

LECOM-A (RS232) EMF2102IBCV004 or

LECOM A/B (RS232/RS485)

EMF2102IBCV001

Automatic / manual operation

Note!

Manual operation is only possible if the motor starter is enabled by the safety

PLC!

X72

1)

- Manual operation

Pin

Signal

Description

Data
Connector: Socket, 8-pin, M12

1

+24 V

Supply (switch in manual operation)

2

Signal 1

Input automatic/manual operation

HIGH

Manual operation

LOW

Automatic operation

3

GND

Reference potential

4

HI1

Input 1

HIGH

CW rotation

5

HI2

Input 2

HIGH

CCW rotation

6 ... 8

Reserved

1)

Designation in production lot with hardware version PB: X20

Advertising