2 establishing of profibus communication, 1 configuration of the host, Configuration of the host – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual
Page 44: Profisafe on board
![background image](/manuals/566239/44/background.png)
PROFIsafe on board
Establishing of PROFIBUS communication
Configuration of the host
6
44
EDSLCMX3024-SPS EN 5.0
6.2
Establishing of PROFIBUS communication
6.2.1
Configuration of the host
Device data base file
By means of the device data base file (GSE file), the PROFIBUS is configured.
Note!
In the GSE file you can select the type of the parameter data channel used
(DRIVECOM or PROFIdrive) and the number of the process data words.
Settings on the master
In the GSE file ”LENZ0951.GSE” you’ll find the configurations:
Module
Parameter data
with consistency
Process data
with/without consistency
Occupied
I/O memory
Safety (4W)
-
4 words with consistency
2 words
Drivecom-PAR (cons.)
+ PCD (nW)
DRIVECOM
n words without consistency
4 + n words
Drivecom-PAR (cons.)
+ PCD (nW cons)
n words with consistency
4 + n words
PCW (cons.)
+ PCD (nW)
PCW
n words without consistency
4 + n words
PCW (cons.)
+ PCD (nW cons)
n words with consistency
4 + n words
PCD (nW)
Without parameter data channel
n words without consistency
n words
PCD (nW cons)
Without parameter data channel
n words with consistency
n words
nW = 1 word ... 10 words
Procedure:
1. Import the GSE file ”LENZ0951.GSE” for the motor starter in the master.
2. Select the ”Safety (4W)” module received in the GSE file and copy (drag & drop) it to
slot 1.
3. Select one of the other modules and copy it to slot 2.
Adaptation of the device controls
Tip!
Use total consistency
ƒ
Please note that the processing of consistent data varies between hosts.
This must be considered in the PROFIBUS application program.
ƒ
Detailed description of consistency: see appendix