Commissioning, Code table – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual

Page 152

Advertising
background image

Commissioning

Code table

8

152

EDSLCMX3024-SPS EN 5.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.
C0410

uSEr

Configuration of

digital input signals

Linking of external signal sources with

internal digital signals

Code is individually adjustable in

four parameter sets

1 Motor 1 start/stop

1

Digital input E1

Start motor 1

HIGH

HIGH

Stop motor 1

LOW

2 Motor 2 start/stop

or direction of

rotation

2

Digital input E2

Start motor 2 or CCW

rotation

HIGH

Stop motor 2 or CW

rotation

LOW

3 Control of brake 1

3

Digital input E3

Release brake 1

HIGH

Engage brake 1

LOW

4 Control of brake 2

4

Digital input E4

Release brake 2

HIGH

Engage brake 2

LOW

5 Reserved

255

Not assigned

...

6 Reserved

255

7 Selection of

mains-side field

rotation direction

255

Not assigned

Only active for motor starter

ELCAMZI as of SW 3.4
Clockwise rotating

field

LOW

Anti-clockwise

rotating field

HIGH

8 Reserved

255

Not assigned

...

9 Reserved

255

10 Inhibit/enable

motor starter

230

Fixed 1 (HIGH)

(selection 30 in C0415)

Enable motor starter

HIGH

Inhibit motor starter

LOW

11 External fault

255

Not assigned

No fault

LOW

External fault active

HIGH

12 Fault reset

255

Not assigned

LOW-HIGH edge resets fault

13 DCTRL1-PAR2/4

255

Not assigned

14 DCTRL1-PAR3/4

255

Not assigned

15 Motor current

selection for the

output to the

PROFIBUS

255

Not assigned

Selection of the motor current

that is output via the bus. The

motor currents thus can be

output via a PROFIBUS word. The

output in two separate words

also is possible.
Current of motor 2

HIGH

Current of motor 1

LOW

16

255

Not assigned

...

...

24 Reserved

255

Not assigned

Advertising