PROFIsafe on board

Parameter data transfer

PROFIdrive parameter data channel (DP-V1, acyclic)

6

72

EDSLCMX3024-SPS EN 5.0

Error code list

Error code

Description

Explanation

Additional

information

0x0000

Impermissible

parameter number

Access to unavailable parameter

-

0x0001

Parameter value

cannot be changed

Change access to a parameter value that cannot be

changed

Subindex

0x0002

Low or high value

limit exceeded

Change access with value outside the value limits

Subindex

0x0003

Faulty subindex

Access to unavailable subindex

Subindex

0x0004

No array

Access with subindex to non-indexed parameter

-

0x0005

Incorrect data type

Change access with value that does not match the data

type of the parameter

-

0x0006

Setting not permitted

(can only be reset)

Change access with value unequal to 0 where this is not

permitted

Subindex

0x0007

Description element

cannot be changed

Change access to a description element that cannot be

changed

Subindex

0x0008

Reserved

(PROFIdrive Profile V2: PPO-Write requested in IR not

available)

-

0x0009

No description data

available

Access to unavailable description (parameter value is

available)

-

0x000A

Reserved

(PROFIdrive Profile V2: Access group wrong)

-

0x000B

No operation priority Change access without rights to change parameters

-

0x000C

Reserved

(PROFIdrive Profile V2: Wrong password)

-

0x000D

Reserved

(PROFIdrive Profile V2: Text cannot be read in cyclic data

transfer)

-

0x000E

Reserved

(PROFIdrive Profile V2: Name cannot be read in cyclic data

transfer)

-

0x000F

No text array

available

Access to text array that is not available (parameter value

is available)

-

0x0010

Reserved

(PROFIdrive Profile V2: No PPO-Write)

-

0x0011

Request cannot be

executed because of

operating state

Access is temporarily not possible for reasons that are not

specified in detail

-

0x0012

Reserved

(PROFIdrive Profile V2: Other error)

-

0x0013

Reserved

(PROFIdrive Profile V2: Data cannot be read in cyclic data

transfer)

-

0x0014

Value impermissible

Change access with a value that is within the value limits

but is not permissible for other long-term reasons

(parameter with defined single values)

Subindex

0x0015

Response too long

The length of the current response exceeds the maximum

transmittable length

0x0016

Parameter address

impermissible

Illegal value or value which is not supported for the

attribute, number of subindexes, parameter number or

subindex or a combination

0x0017

Illegal format

Write request: Illegal format or format of the parameter

data which is not supported

0x0018

Number of values not

consistent

Write request: Number of the values of the parameter

data does not match the number of subindexes in the

parameter address

...
to 0x0064

Reserved

-

-

0x0065

...

0x00FF

Manufacturer-specific -

-

Advertising