Code table

8

148

EDSLCMX3024-SPS EN 5.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.
C0126

Behaviour in case

of communication

error

2

Monitored communication channel

0

All monitoring is deactivated

1

Reserved

2

Monitoring of internal communication

active

A communication abort with

activated monitoring initiates

TRIP CE5

4

Reserved

8

Reserved

C0135

Motor starter

control word

(parameter

channel)

Control of the motor starter via parameter channel.

The most important control commands are

summarised in bit commands

C0135 cannot be changed by

means of the diagnosis terminal

Bit

Assignment

0

Motor 1 start/stop

0 Stop motor 1
1 Start motor 1

1

Motor 2 start/stop or selection of

direction of rotation

0 Stop motor 2 or CCW rotation
1 Start motor 2 or CW rotation

2

Control of brake 1

0 Engage brake 1
1 Release brake 1

3

Control of brake 2

0 Engage brake 2
1 Release brake 2

4 ... 5

Reserved

6

Selection of mains-side field rotation

direction

Only active for motor starter

ELCAMZI as of SW 3.4

0 Clockwise rotating field
1 Anti-clockwise rotating field

7 ... 8

Reserved

9

Enable/inhibit motor starter

0 Enable motor starter
1 Inhibit motor starter

10

TRIP set

Sets fault ”external error” (EEr ,

LECOM No. 91)

0 External error active
1 No fault

11

TRIP reset

Cause of malfunction has to be

eliminated

1 ⇒ 0 Edge resets fault

12

Reserved

...
15