Commissioning, Code table – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual
Page 157

Commissioning
Code table
8
157
EDSLCMX3024-SPS EN 5.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0517*
User menu
z
After mains switching or in
the function, the code
from C0517/1 is displayed.
z
Enter the number of the
desired codes in the subcodes
The codes C0518 ... C0606
cannot be entered in the user
menu!
1 Memory 1
54
C0054
Apparent current of motor 1
2 Memory 2
55
C0055
Apparent current of motor 2
3 Memory 3
6
C0006
LCD display language
4 Memory 4
120
C0120
Rated motor current
5 Memory 5
410
C0410
Configuration of digital input signals
6 Memory 6
415
C0415
Configuration of digital output signals
7 Memory 7
12
C0012
Acceleration time
8 Memory 8
423
C0423
Brake switch-on delay
9 Memory 9
424
C0424
Brake switch-off delay
10 Memory 10
2
C0002
Parameter set management
C0518 Service codes
Changes by Lenze service only!
C0519
C0520
C0600
Service codes
Changes by Lenze service only!
...
C0604
C0605
Status of service
switch and digital
inputs
Read only
Representation in hex
Bit
Status
0
Service switch
0 ”OFF” position
1 ”ON” position
1
Level on E1
The actual level without
evaluation by C0411 is
displayed.
0 LOW
1 HIGH
2
Level on E2
0 LOW
1 HIGH
3
Level on E3
0 LOW
1 HIGH
4
Level on E4
0 LOW
1 HIGH
C0606
Status of digital
outputs
Read only
Representation in hex
Bit
Status
0
Level on A1
The actual level without
evaluation by C0416 is
displayed.
0 LOW
1 HIGH
1
Level on E2
0 LOW
1 HIGH
C1700
Service codes
Changes by Lenze service only!
...
C1799