3 technical data, 1 general data and operating conditions, Technical data – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual
Page 15: 3technical data
![background image](/manuals/566239/15/background.png)
Technical data
General data and operating conditions
3
15
EDSLCMX3024-SPS EN 5.0
3
Technical data
3.1
General data and operating conditions
General data
Values
Conformity
CE
Low-Voltage Directive (73/23/EEC)
EMC Directive (93/68/EEC)
Standards
DIN EN 60947-4-2 Semiconductor motor control units and motor starters for
AC voltage
EN954 KAT3
Safe torque off (STO) according to category 3
General technical data
Values
EMC
Compliance with the requirements in accordance with EN 60947-4-2
Noise emission
Compliance with limit class B in accordance with EN 60947-4-2
Leakage current to PE
(according to EN 50178)
< 3.5 mA
Enclosure
IP 54
All connectors that are not used have to be closed by
means of protection covers or blanking plugs.
NEMA 250 type 4
Protective measures against
Motor overtemperature
(input for PTC or thermal contact, I
2
t monitoring)
Protective insulation of control
circuits
Safe disconnection from mains:
double/reinforced insulation to EN 50178
Insulation resistance
Overvoltage category III to VDE 0110
Service switch
Rotary switch, triple locking
reset feedback contact for status message and fault message (TRIP reset)