2 description, Description, Safety engineering – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual

Page 121

Advertising
background image

Safety engineering

Safety functions

Description

7

121

EDSLCMX3024-SPS EN 5.0

7.5.2

Description

7.5.2.1

Overview
Functions

ƒ

Safe torque off (STO).
(formerly: safe standstill, protection against unexpected start-up)

ƒ

Connection of safety sensors.

ƒ

PROFIsafe safety bus connection:
The transmission of safe information via the PROFIsafe protocol according to the

”PROFIsafe - Profile for Safety Technology” specification, version 1.30, of the PROFIBUS

user organisation (PUO) is supported.

ƒ

The safe inputs and safe outputs do not affect local functions in the device. They are

evaluated and controlled exclusively via PROFIsafe.

Danger!

If the request for the safety function is cancelled, the drive will restart

automatically.
You must provide external measures which ensure that the drive only restarts

after a confirmation (EN 60204).

7.5.2.2

Safety category
The implemented safety functions meet the requirements of the standards:

ƒ

Control category 3 according to EN 954-1
In order to comply with category 3, the external wiring and cable monitoring must also

meet the requirements of category 3.

Advertising