3 error states, Error states, Safety engineering – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual

Page 122

Advertising
background image

Safety engineering

Safety functions

Error states

7

122

EDSLCMX3024-SPS EN 5.0

7.5.3

Error states

Error states with specific responses are assigned to recognised errors or maloperation of

the drive. Via the error states, the response can be adopted to the entire drive.

Features

Error status

System error

Error

Event

Fatal internal error

Error

LED ”ME”

On

Blinking

Safety engineering status

Lockout (CPU stopped)

Error status

The control category in accordance

with EN 954-1 ...

... has been exited

... has been exited

Response

The motor is immediately switched to torque-free operation via STO.

Confirmation after deactivated

event

z

Switch-off and switch-on of the

24-V supply

z

Via PROFIsafe

z

Switch-off and switch-on of the

24-V supply

Response to the confirmation

The PROFIsafe communication is interrupted.

Tab. 7-3

Overview of error states

If errors occur in the PROFIsafe communications, the data from the PROFIsafe driver is

passivated. The STO function is activated.
After reinitialisation of the PROFIsafe communication, the drive is automatically

re-enabled if no standstill function is selected.

Note!

If the system error also occurs after switching the 24-V supply, please contact

the service.