Page 113: Safe inputs and safe outputs technical data

Advertising
background image

Safety engineering

Safe inputs and safe outputs

Technical data

7

113

EDSLCMX3024-SPS EN 5.0

7.4.2

Technical data

Detail characteristics of the safe inputs and safe outputs
Signal

Specification

Min.

Typ.

Max.

I1A, I1B

I2A, I2B

I3A, I3B

I4A, I4B

PLC input, IEC-61131-2, 24 V, type 1
LOW signal

[V]

-3

0

5

Input current

[mA]

15

HIGH signal

[V]

15

24

30

Input current

[mA]

2

15

Input capacitance

[nF]

3.3

Switch-off time (depending on the standard device)

[ms]

2

4

Switch-on time

[ms]

2

4

Input delay (tolerated test pulse)

[ms]

1

CLA, CLB

PLC output, IEC-61131-2, 24 V DC, 50 mA
Supply voltage of the outputs

[V]

18

24

30

LOW signal

[V]

0

0.8

HGH signal

[V]

17

24

29

Output current

[mA]

50

Width of test pulse

[μs]

750

Frequency of test pulse

[s]

1

1.8

3

Specific resistance of a passive sensor

[kΩ]

2

O1A, O1B

O2A, O2B

PLC output, IEC-61131-2, 24 V DC, short-circuit-proof
Supply voltage of the outputs

[V]

18

24

30

Output voltage for LOW signal

[V]

0

0.8

Output voltage for HIGH signal

[V]

17

24

29

Output current

[mA]

500

Width of test pulse

[μs]

750

900

Frequency of test pulse

[s]

1

1.8

3

Tab. 7-1

Technical data