PROFIsafe on board
Process data transfer
Device control
6
49
EDSLCMX3024-SPS EN 5.0
6.3.1.2
Process data signals for motor starters
Configuration of process output data
The assignment of the max. 10 process data output words (POW) of the master to bit
control commands or setpoints of the motor starter can be freely configured via C1511.
ƒ
You can set up a freely selectable Lenze device control using the FIF control words
( 50).
Note!
When C1511 is modified, the process output data is automatically inhibited in
order to ensure data consistency.
Use C1512 to reenable individual or all POWs.
Configuration of process output data
Code
Subcode
Index
LENZE setting
Data type
C1511
23064
d
=
5A18
h
1
Control word (FIF-CTRL1)
FIX32
1 (POW1)
2 (POW2)
3 (POW3)
4 (POW 4)
5 (POW 5)
6 (POW 6)
7 (POW 7)
8 (POW 8)
9 (POW 9)
10 (POW 10)
Tip!
For the description of the complete code see ( 88)