PROFIsafe on board
Process data transfer
Device control
6
52
EDSLCMX3024-SPS EN 5.0
The bit assignments for the applicable status words can be gathered from the following
table:
Bit
Status word 1 (FIF-STAT1)
Status word 2 (FIF-STAT2)
Assignment
Assignment
0
Image of C0417/1
Image of C0418/1
1
Image of C0417/2
Image of C0418/2
2
Image of C0417/3
Image of C0418/3
3
Image of C0417/4
Image of C0418/4
4
Image of C0417/5
Image of C0418/5
5
Image of C0417/6
Image of C0418/6
6
Image of C0417/7
Image of C0418/7
7
Controller inhibit
Image of C0418/8
0
1
Motor starter enabled
Motor starter inhibted
8
Bits 11 ... 8
Device status
Image of C0418/9
9
Image of C0418/10
10
Image of C0418/11
11
Image of C0418/12
11
10
9
8
0
0
1
1
Operation inhibited
0
1
1
0
Operation enabled
1
0
0
0
Fault active
1
1
1
1
Communication with standard
device not possible
12
Overtemperature warning
Image of C0418/13
0
1
No warning
Housing temperature > +75 °C
13
Image of C0417/14
Image of C0418/14
14
Image of C0417/15
Image of C0418/15
15
Image of C0417/16
Image of C0418/16
Note!
The status words FIF-STAT1 and FIF-STAT2 are freely configurable via the codes
C0417 or C0418.