Safety engineering – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual

Page 133

Advertising
background image

Safety engineering

Safety functions

Safe PROFIsafe connection

7

133

EDSLCMX3024-SPS EN 5.0

PROFIsafe parameters
These PROFIsafe parameters and contents are supported:

PROFIsafe parameters
Name

Description

Valid contents

F_Source_Add

PROFIsafe source address of the safety PLC

0x01 ... 0xFFFE

F_Dest_Add

PROFIsafe target address of the device

0x01 ... 0xFFFE

F_WD_Time

PROFIsafe monitoring time of the device

110 ... 65535 ms

F_Check_SeqNo

Check sequence no. in CRC

0

F_Check_iPar

Check iparameters CRC3 in CRC

0

F_SIL

Supported SIL (Safety Integrity Level)

0

Æ

SIL1

1

Æ

SIL2

2

Æ

SIL3

F_CRC_Length

Length of CRC

1

F_Block_ID

Identification of the parameter type

0

F_Par_Version

Version of the safety layer

0

F_Par_CRC

Cyclic CRC

Is calculated

Tab. 7-15

Supported PROFIsafe parameters