Safety engineering – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual
Page 133
Advertising
Safety engineering
Safety functions
Safe PROFIsafe connection
7
133
EDSLCMX3024-SPS EN 5.0
PROFIsafe parameters
These PROFIsafe parameters and contents are supported:
PROFIsafe parameters
Name
Description
Valid contents
F_Source_Add
PROFIsafe source address of the safety PLC
0x01 ... 0xFFFE
F_Dest_Add
PROFIsafe target address of the device
0x01 ... 0xFFFE
F_WD_Time
PROFIsafe monitoring time of the device
110 ... 65535 ms
F_Check_SeqNo
Check sequence no. in CRC
0
F_Check_iPar
Check iparameters CRC3 in CRC
0
F_SIL
Supported SIL (Safety Integrity Level)
0
Æ
SIL1
1
Æ
SIL2
2
Æ
SIL3
F_CRC_Length
Length of CRC
1
F_Block_ID
Identification of the parameter type
0
F_Par_Version
Version of the safety layer
0
F_Par_CRC
Cyclic CRC
Is calculated
Tab. 7-15
Supported PROFIsafe parameters
Advertising