3 display elements, Safety engineering, Display elements – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual

Page 111

Advertising
background image

Safety engineering

Display elements

7

111

EDSLCMX3024-SPS EN 5.0

7.3

Display elements

Status display: drive-based safety

lcu121_000h

Pos.

Colour

State

Description

MS

Green

On

Integrated safety technology has been properly initialised.

Off

Integrated safety technology has not been initialised.

Confirmation is not possible.

EN

Yellow

On

Controller enabled

Off

Non-safe display ”STO”

ME

Red

On

System error:

z

After a serious internal error STO is activated.

z

Reset is only possible by switching the 24-V supply.

Blinking

Error:

z

After an internal error or an error on the safe inputs or

outputs, STO is activated.

z

The safety class is exited.

z

Confirmation is possible.

Off

Error-free operation

PS

Red

On

Error PROFIsafe:

z

Communication is not possible.

z

Acknowledgement is possible.

Blinking

No valid PROFIsafe configuration

Off

PROFIsafe is error-free.

SI1

Green

On

Channels A and B are ON

Off

At least one channel is OFF

SI2

Green

On

Channels A and B are ON

Off

At least one channel is OFF

SI3

Green

On

Channels A and B are ON

Off

At least one channel is OFF

SI4

Green

On

Channels A and B are ON

Off

At least one channel is OFF

SO1

Yellow

On

Channels A and B are ON

Off

Channels A and B are OFF

SO2

Yellow

On

Channels A and B are ON

Off

Channels A and B are OFF

Advertising