PROFIsafe on board

Parameter data transfer

DRIVECOM parameter data channel (DP-V0, cyclic)

6

57

EDSLCMX3024-SPS EN 5.0

Parameter value (data)
Depending on the data format, the length of the parameter value is between 1 to 4 bytes.

Data is saved in the Motorola format, i.e. first the high byte or high word, then the low byte

or low word.

Byte 5

Byte 6

Byte 7

Byte 8

High byte

Low byte

High byte

Low byte

High word

Low word

Double word

Assignment of bytes 5 .. 8 with parameter values of different lengths

Byte 5

Byte 6

Byte 7

Byte 8

Parameter value

(length 1)

00

00

00

Parameter value (length 2)

00

00

Parameter value (length 4)

Note: Strings or data blocks cannot be transmitted.
Error messages
The following error messages may appear:

Data 1

Data 2

Data 3

Data 4

Meaning

6

3

00

00

No right to access

6

5

10

Impermissible job parameter

6

5

11

Invalid subindex

6

5

12

Data length too large

6

5

13

Data length too small

6

6

00

Object is no parameter

6

7

00

Object does not exist

6

8

00

Data types do not correspond

8

0

00

Job cannot be executed

8

0

20

Job cannot be executed at the moment

8

0

21

Not executable because of local control

8

0

22

Not executable because of device status

8

0

30

Out of value range/parameter can only be changed with inhibited

controller

8

0

31

Parameter value too large

8

0

32

Parameter value too small

8

0

33

Subparameter out of value range

8

0

34

Subparameter value too large

8

0

35

Subparameter value too small

8

0

36

Maximum value smaller than minimum value

8

0

41

Communication object cannot be mapped on process data

8

0

42

Process data length exceeded

8

0

43

General collision with other values

Data contents in hexadecimal format