Profisafe on board – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual
Page 89
Advertising
![background image](/manuals/566239/89/background.png)
PROFIsafe on board
Code table
Communication-relevant Lenze codes
6
89
EDSLCMX3024-SPS EN 5.0
C1512:
Enable process output data
Code
Subcode
Index
Possible settings
Data type
Lenze
Selection
C1512**
23063
d
=
5A17
h
1
1
[1]
65535 FIX32
When C1511 is changed, the process output data are automatically inhibited in order to
ensure data consistency.
Use C1512 to reenable individual or all POWs.
By means of the different decimal values of the bit positions, any combinations of process
data output words can be enabled.
ƒ
0 = Inhibit output word
ƒ
1 = Enable output word
Value of bit positions
POW 10
POW 9
...
POW 2
POW 1
2
9
2
8
2
1
2
0
The value 65535 (FFFF
hex
) in code C1512 enables all process output data.
Advertising
This manual is related to the following products: