PROFIsafe on board

Parameter data transfer

DRIVECOM parameter data channel (DP-V0, cyclic)

6

56

EDSLCMX3024-SPS EN 5.0

Byte 2: subindex
Additional addressing via the subindex is required for those codes that have a subcode (see

code table).
Example:
Code C0012 / subcode 2 addresses motor 2 acceleration time

Byte 3 / 4: index

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Service

Subindex

Index

High byte

Index

Low byte

Data 4 /

Error 4

Data 3 /

Error 3

Data 2 /

Error 2

Data 1 /

Error 1

The parameters or the Lenze codes are selected with these two bytes according to the

formula:
Index = 24575 - Lenze code number
Example:

The parameter C0012 (acceleration time) is to be addressed:
24575 - 12 = 24563 = 5FF3

hex

The entries for this example would be:

ƒ

Byte 3: Index high byte = 5F

hex

ƒ

Byte 4: Index low byte = F3

hex

Byte 5 - 8:

Parameter value (data) or error information (error)

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Service

Subindex

Index

High byte

Index

Low byte

Data 4 /

Error 4

Data 3 /

Error 3

Data 2 /

Error 2

Data 1 /

Error 1

The status of the (”status”) bit 7 in byte 1 (”service”) determines the meaning of this data

field:

Meaning of bytes 5 - 8 if
bit 7 = 0

bit 7 = 1

Parameter value (data 1 - 4 )

Error information (error 1 - 4) for an invalid access.