PROFIsafe on board

Code table

Communication-relevant Lenze codes

6

88

EDSLCMX3024-SPS EN 5.0

C1511:

Configuration of process output data

Code

Subcode

Index

Possible settings

Data type

Lenze

Selection

C1511

23064

d

=

5A18

h

1

1 ... 16

FIX32

1 (POW1)

see table below

2 (POW2)
3 (POW3)
4 (POW 4)
5 (POW 5)
6 (POW 6)
7 (POW 7)
8 (POW 8)
9 (POW 9)
10 (POW 10)

The process data output words (POW) of the master can be freely assigned to bit control

commands or setpoints of the controller via C1511.

Selection

Scaling

1

FIF control word 1 (FIF-CTRL1)

16 bits

2

Reserved

16 bits

3

Reserved

4

Reserved

5

Reserved

6

Reserved

7

Reserved

8

Reserved

9

Reserved

10

Reserved

11

Reserved

12

Reserved

13

FIF-IN.W1

16 bits or 0 ... 65535

14

FIF-IN.W2

16 bits or 0 ... 65535

15

Reserved

16

Reserved