5 code table, Commissioning – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual
Page 144
![background image](/manuals/566239/144/background.png)
Commissioning
Code table
8
144
EDSLCMX3024-SPS EN 5.0
8.5
Code table
Tip!
The following code table describes the device parameters. The parameters for
the communication via PROFIBUS can be found in chapter 6: ( 84)
How to read the code table
Column
Abbreviation
Meaning
Code
Cxxxx
Code Cxxxx
Parameter value is accepted immediately (ONLINE)
1
Subcode 1 of Cxxxx
2
Subcode 2 of Cxxxx
Cxxxx
Altered parameter of the code is accepted after has been pressed
Cxxxx
Altered parameter of the code is accepted after has been pressed if the controller
is inhibited
uSEr
In the Lenze setting, code is available in the uSEr menu. The uSEr menu is active after
every mains connection.
Designation
Designation of the code
Lenze
Lenze setting (value at delivery or after restoring the delivery status via C0002)
Æ
The column ”IMPORTANT” contains further information
Selection
1
{%}
99 Min. value
{unit} max. value
IMPORTANT
-
Short, important explanations
Code
Possible settings
IMPORTANT
No.
Designation
Lenze
Selection
C0002
uSEr
Parameter set
management
0
0
Ready
PAR1 ... PAR4:
z
Parameter sets of the
standard device
z
In PAR1 ... PAR4, C0005,
C0408, C0409, C0410 and
C0411 are individually
adjustable
FPAR1:
z
Module-specific parameter
set for PROFIBUS-DP
z
FPAR1 is stored in the
function module