3 mains connection, Electrical installation – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual
Page 27
Advertising
![background image](/manuals/566239/27/background.png)
Electrical installation
Mains connection
5
27
EDSLCMX3024-SPS EN 5.0
5.3
Mains connection
lcu12x_000c
X10 - Mains connection
Pin
Connection
Description
Data
Connector: Pins, Harting HAN-Modular
a1
L1
Phase L1
3/PE AC 320 V - 0% ... 530 V + 0%
a2
L2
Phase L3
a3
L3
Phase L3
PE
PE conductor
X11 - 24 V DC connection
Pin
Connection
Description
Data
Connector: Pins, Harting HAN-Modular
b1
24 V DC
Voltage supply for control electronics
Safely separated power supply unit
(SELV/PELV)
+24 V DC
(+20 V DC - 0% ... +26.5 V DC + 0%)
Max. 5 A
b2
n. c.
Not assigned
b3
GND
Reference potential
Advertising
This manual is related to the following products: