3 mains connection, Electrical installation – Lenze ELCAMZIxxx4SNNPSNN (LCU122) User Manual

Page 27

Advertising
background image

Electrical installation

Mains connection

5

27

EDSLCMX3024-SPS EN 5.0

5.3

Mains connection

lcu12x_000c

X10 - Mains connection
Pin

Connection

Description

Data
Connector: Pins, Harting HAN-Modular

a1

L1

Phase L1

3/PE AC 320 V - 0% ... 530 V + 0%

a2

L2

Phase L3

a3

L3

Phase L3

PE

PE conductor

X11 - 24 V DC connection
Pin

Connection

Description

Data
Connector: Pins, Harting HAN-Modular

b1

24 V DC

Voltage supply for control electronics

Safely separated power supply unit

(SELV/PELV)

+24 V DC

(+20 V DC - 0% ... +26.5 V DC + 0%)

Max. 5 A

b2

n. c.

Not assigned

b3

GND

Reference potential

Advertising