Commissioning

Code table

8

155

EDSLCMX3024-SPS EN 5.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.
C0415

uSEr

(Cont.)

22

Active mains-side rotating field

Only active for motor starter

ELCAMZI as of SW 3.4
Clockwise rotating

field

LOW

Anti-clockwise

rotating field

HIGH

23

Error ”Mains failure”

24

Safety engineering active

HIGH = motor starter in ”STO”

status (safe torque off)

25

TRIP fault message

26

Motor 1 or motor 2 is running

27 ... 28 Reserved
29

Fixed 0

Signal always is ”LOW”

30

Fixed 1

Signal always is ”HIGH”

31

Reserved

32

Digital input E1

33

Digital input E2

34

Digital input E3

35

Digital input E4

36 ... 39 Reserved
40 ... 55 Reserved
60 ... 75 FIF-IN.W1

Bit 0 (60) ... bit 15 (75)

80 ... 95 FIF-IN.W2

Bit 0 (80) ... bit 15 (95)

100 ...

135

Reserved

160

Level on E1

Level on the digital input

without logic operation or

inversion

161

Level on E2

162

Level on E3

163

Level on E4

255

Not assigned

C0416

Level inversion of

digital outputs

A1 ... A2

0

0

A1 ... A2 not inverted (HIGH active)

C0416 can be set differently in

the four parameter sets.

A combination of the terminals

can be inverted by entering the

sum of the selection values.

1

A1 is inverted (LOW active)

2

A2 is inverted (LOW active)