Stratix 5100 Device Manager Parameter Definitions

Time Stamp Format for Future Events

Choose the time format that you want the event time stamp information
saved. The three supported time stamp formats are as follows:
System Uptime

The length of time the system was operational when the event
occurred. Initially, this time is displayed as number of seconds,
growing to minutes, days, and weeks. For example, 1w0d represents
one week and zero days.

Global Standard Time

The time of day the event occurred in UTC time recorded as Month dd
hh:mm:ss.usec and 3-letter time zone (UTC). The system clock must be
set for this time stamp to work.

Local Time

The time of day the event occurred in the local time zone recorded as
Month DD hh:mm:ss.usec and 3-letter time zone. The system clock
must be set for this time stamp to work.

Event Log Size

Determine the size of the buffer you want established for logging
commands. The more memory you assign to the log, the less memory that
is available to switch packets.

History Table Size

Determine the maximum number of syslog messages that you want
stored in the access point's history table.

Table 70 - Event Log Configuration Parameter Descriptions (Continued)