Install the Stratix 5100 Wireless Access Point/Workgroup Bridge

Chapter 2

Checking Power

You can verify the availability of power to the access point/bridge by checking the
power injector

Power status indicator

Green color indicates input power is being supplied to the bridge.
Red color indicates an overcurrent or overvoltage error condition—

disconnect input power from the power injector, check all coax cable
connections for a possible short, wait approximately 1 minute, and
reconnect input power to the power injector. If the status indicator
turns red again, contact technical support for assistance.

Off indicates input power is not available—verify that the power module is
connected to the power injector and that AC power is available.

Operating status

Blinking blue

Software upgrade in progress

Cycling through green, red, and
off

Discovery/join process in progress

Rapidly cycling through blue,
green, and red

Access point location command invoked

Blinking red

Ethernet link not operational

Boot loader warnings

Blinking blue

Configuration recovery in progress (MODE button pushed
for 2…3 seconds)

Red

Ethernet failure or image recovery.
(MODE button pushed for 20…30 seconds)

Blinking green

Image recovery in progress (MODE button released)

Boot loader errors

Red

DRAM memory test failure

Blinking red and blue

Nonvolatile memory file system failure

Blinking red and off

Environment variable failure

Bad MAC address

Ethernet failure during image recovery

Start environment failure

No Cisco image file

Start failure

Cisco IOS errors

Red

Software failure; try disconnecting and reconnecting unit
power

Cycling through blue, green,
red, and off

General warning; insufficient in-line power

TIP

The power injector requires approximately 50 seconds to recover from
an overcurrent or overvoltage condition.