Rockwell Automation 1783-WAPxxx Stratix 5100 Wireless Access Point User Manual User Manual

Page 585

Advertising
background image

Rockwell Automation Publication 1783-UM006A-EN-P - May 2014

585

Error and Event Messages

Appendix C

DOT11-6-CHAN_NOT_AVAIL: “DFS configured

frequency %d Mhz unavailable for %d

minute(s).

Radar has been detected on the current channel. Dynamic
Frequency Selection (DFS) regulations require no
transmission for 30 seconds on the channel.

None.

DOT11-6-DFS_SCAN_COMPLETE: “DFS scan

complete on frequency %d MHz.”

The device has completed its Dynamic Frequency Scan
(DFS) frequency scanning process on the displayed
frequency.

None.

DOT11-6-DFS_SCAN_START: “DFS: Scanning

frequency %d MHz for %d seconds.”

The device has begun its DFS scanning process.

None.

DOT11-6-DFS_TRIGGERED: “DFS: triggered on

frequency %d MHz.”

DFS has detected RADAR signals on the indicated
frequency.

None. The channel is placed on the non-
occupancy list for 30 minutes and a new
channel is selected.

DOT11-4-DFS_STORE_FAIL: “DFS: could not

store the frequency statistics.”

A failure occurred writing the DFS statistics to flash.

None.

DOT11-4-NO_SSID: “No SSIDs configured, %d

not started.”

All SSIDs were deleted from the configuration. At least
one must be configured for the radio to run.

Configure at least one SSID on the access
point.

DOT11-4-NO_SSID_VLAN: “No SSID with VLAN

configured. %s not started.”

No SSID was configured for a VLAN. The indicated
interface was not started.

At least one SSID must be configured per
VLAN. Add at least one SSID for the VLAN on
the indicated interface.

DOT11-4-NO_MBSSID_VLAN: “No VLANs

configured in MBSSID mode. %s not

started.”

No VLAN configured in MBSSID mode. The indicated
interface was not started.

Add at least one SSID with the VLAN on the
indicated interface configuration.

DOT11-4-NO_MBSSID_SHR_AUTH: “More than 1

SSID with shared authentication method in

non-MBSSID mode % is down”.

Not more than 1 SSID can have shared authentication
method when MBSSID is not enabled.

Remove Dot11Radio radio interface or
change authentication mode for SSID to open
configuration.

DOT114-NO_MBSSID_BACKUP_VLAN: “Backup

VLANs cannot be configured if MBSSID is

not enabled. %s not started.

To enable a backup VLAN, configure the MBSSID mode.

Configure MBSSID on the device.

IF-4-MISPLACED_VLAN_TAG: “Detected a

misplaced VLAN tag on source Interface %.

Dropping packet.

Received an 802.1Q VLAN tag was detected on the
indicated interface that could not be parsed correctly. The
received packet was encapsulated or deencapsulated
incorrectly.

None

DOT11-2-FW_LOAD_NET: “Interface %s cannot

load on boot. Place image in flash root

directory and reload.”

The radio images cannot be loaded from a network when
the access point starts.

Place the image on the root directory of the
flash file-system.

DOT11-4-FW_LOAD_DELAYED: “Interface %s,

network filesys not ready. Delaying

firmware (%s) load.”

The network file-system was not running or not ready
when trying to upgrade new firmware into the indicated
interface. Loading the identified firmware file has been
delayed.

Make sure the network is up and ready
before attempting to upgrade the new
firmware.

DOT11-3-FLASH_UNKNOWN_RADIO: “Interface

%s has an unknown radio.”

The radio type could not be determined when the user
attempted to upgrade

new firmware into the indicated

interface.

Restart the system and see if the firmware
upgrade completes.

DOT11-4-UPLINK_ESTABLISHED: “Interface

%s associated to AP %s %e %s.

The indicated repeater has associated to the indicated root
access point. Clients can now associate to the indicated
repeater and traffic can pass.

None.

DOT11-2-UPLINK_FAILED: “Uplink to parent

failed: %s.”

The connection to the parent access point failed for the
displayed reason. The uplink stops the connection
attempts.

Try resetting the uplink interface. Contact
Technical Support if the problem persists.

DOT11-4-CANT_ASSOC: “Interface %, cannot

associate %s.”

The indicated interface device could not associate to an
indicated parent access point.

Check the configuration of the parent access
point and this unit to make sure there is a
match.

DOT11-4-CANT_ASSOC: “Interface

Dot11Radio 0, cannot associate.”

Parent does not support client MFP. This error message
appears on the access point only in workgroup bridge,
repeater, or non-root bridge mode and is seen if the WGB,
repeater, or non-root is configured with Client MFP SD
required (or mandatory) but root Client MFP is disabled.

Check the configuration of the parent access
point and this unit to make sure there is a
match.

Table 6 - Subsystem Messages (Continued)

Message

Explanation

Recommended Action

Advertising