Lwapp error messages, Sensor messages, Lwapp error messages sensor messages – Rockwell Automation 1783-WAPxxx Stratix 5100 Wireless Access Point User Manual User Manual

Page 592

Advertising
background image

592

Rockwell Automation Publication 1783-UM006A-EN-P - May 2014

Appendix C

Error and Event Messages

LWAPP Error Messages

Sensor Messages

Message

Explanation

Recommended Action

LWAPP-3-CDP: Failure sending CDP Update

to Controller. Reason “s”

Could not send access point CDP update to controller

No action is required.

LWAPP-3-CLIENTERRORLOG: “s”

This log message indicates an LWAPP client error event.
The message is logged to help in troubleshooting LWAPP
access point join problems.

No action is required.

LWAPP-3-CLIENTEVENTLOG: “s”

This log message indicates an LWAPP client notification
event. The message is logged to help in troubleshooting
LWAPP access point join problems.

No action is required.

LWAPP-3-UNSUPPORTEDRM: Got unsupported

CCX RM Measurement “s” request “d” from

Controller.

Got unsupported CCX radio managment measurement
request from controller.

No action is required.

LWAPP-5-WRONG_DFS_SLOT: DFS action on

non-DFS radio “d”

DFS action on radio b/g

No action is required.

Message

Explanation

Recommended Action

SENSOR-3-TEMP_CRITICAL: System sensor “d”

has exceeded CRITCAL temperature

thresholds

One of the measured environmental test points exceeds
the extreme threshold.

Correct the specified condition, or the system
can shut itself down as a preventive measure.
Enter the

show environment all

command to help determine if this is due to
temperature or voltage condition. If this is a
critical temperature warning, please verify
that the router fans are operating and that
the room cooling and air-conditioning are
functioning. This condition could cause the
system to fail to operate properly.

SENSOR-3-TEMP_NORMAL: “s” temperature

sensor is now normal

One of the measured environmental test points is under
normal operating temperature.

None required.

SENSOR-3-TEMP_SHUTDOWN: Shuting down the

system because of dangerously HIGH

temperature at sensor “d”.

One of the measured environmental test points exceeds
the operating temperature environment of the router.

Investigate the cause of the high
temperature.

SENSOR-3-TEMP_WARNING: “s” temparature

sensor “d” has exceeded WARNING

temperature thresholds

One of the measured environmental test points exceeds
the warning threshold.

Closely monitor the condition and correct if
possible, by cooling the environment.

SENSOR-3-VOLT_CRITICAL: System sensor “d”

has exceeded CRITCAL voltage thresholds

One of the measured environmental test points exceeds
the extreme voltage threshold.

Correct the specified condition, or the system
can shut itself down as a preventive measure.
Enter the

show environment all

command to help determine if this is due to
voltage condition. This condition could cause
the system to fail to operate properly.

SENSOR-3-VOLT_NORMAL: System sensor

“d”(“d”) is now operating under NORMAL

voltage

One of the measured environmental test points is under
normal operating voltage.

None required.

SENSOR-3-VOLT_WARNING: Voltage monitor

“d”(“d”) has exceeded voltage thresholds

One of the measured voltage test points indicates that
voltage is out of normal range.

Check Power Supplies or contact TAC.

Advertising