Adjusting radio access categories – Rockwell Automation 1783-WAPxxx Stratix 5100 Wireless Access Point User Manual User Manual

Page 472

Advertising
background image

472

Rockwell Automation Publication 1783-UM006A-EN-P - May 2014

Chapter 16

Configuring QoS

This is used to rate-limit the upstream traffic originating from each of the non-
roots to root bridge incase of P2MP setup. To do rate-limiting on downstream
traffic, class-maps are applied at the root-side router/switch.

Adjusting Radio Access Categories

The access point uses the radio access categories to calculate backoff times for
each packet. As a rule, high-priority packets have short backoff times.

The default values in the Min and Max Contention page fields and in the Slot
Time fields are based on settings recommended in IEEE Draft Standard 802.11e.
For detailed information on these values, consult that standard.

The values listed in this table are to the power of 2. The access point computes
Contention page values with this equation:

CW = 2 ** X minus 1

where X is the value from

Table 107 on page 472

.

IMPORTANT

Rate-limiting can be applied only to ethernet ingress.

IMPORTANT

Use the default settings on the Radio Access Categories page. Changing these
values can lead to unexpected blockages of traffic on your wireless LAN, and
the blockages can be difficult to diagnose. If you change these values and find
that you need to reset them to defaults, use the default settings listed in

Table 107 on page 472

.

Table 107 - Default QoS Radio Access Categories

Class of Service

Min
Contention page

Max Contention page

Fixed Slot Time

Transmit Opportunity

Admission Control

Local

Cell

Local

Cell

Local

Cell

Local

Cell

Local

Cell

Background

4

10

6

0

Best Effort

4

10

2

0

Video <100 ms Latency

3

2

1

3008

Voice <100 ms Latency

2

3

1

1504