13. (Optional) Save your entries in the configuration file.

copy running-config startup-config

After you enable standby mode, configure the settings that you recorded from the
monitored access point to match on the standby access point.

Verifying Standby Operation

Use this command to check the status of the standby access point:

show iapp standby-status

This command provides the status of the standby access point. This table lists the
standby status messages that can appear.

Use this command to check the standby configuration:

show iapp standby-parms

This command provides the MAC address of the standby access point, the
standby timeout, and the poll-frequency values. If no standby access point is
configured, this message

appears:

no iapp standby mac-address

If a standby access point takes over for the monitored access point, you can use
the show iapp statistics command to help determine the reason that the standby
access point took over.

Table 112 - Standby Status Messages

Message

Description

IAPP Standby is Disabled

The access point is not configured for standby mode.

IAPP—AP is in standby mode

The access point is in standby mode.

IAPP—AP is operating in active mode

The standby access point has taken over for the monitored access point
and is functioning as a root access point.

IAPP—AP is operating in repeater mode

The standby access point has taken over for the monitored access point
and is functioning as a repeater access point.

Standby status: Initializing

The standby access point is initializing link tests with the monitored
access point.

Standby status: Takeover

The standby access point has transitioned to active mode.

Standby status: Stopped

Standby mode has been stopped by a configuration command.

Standby status: Ethernet Linktest Failed

An Ethernet link test failed from the standby access point to the
monitored access point.

Standby status: Radio Linktest Failed

A radio link test failed from the standby access point to the monitored
access point.

Standby status: Standby Error

An undefined error occurred.

Standby State: Init

The standby access point is initializing link tests with the monitored
access point.

Standby State: Running

The standby access point is operating in standby mode and is running link
tests to the monitored access point.

Standby State: Stopped

Standby mode has been stopped by a configuration command.

Standby State: Not Running

The access point is not in standby mode.