Configuring Repeater and Standby Access Points and Workgroup Bridge Mode

Chapter 20

The table below lists the possible status values of the standby access point.

Configuring a Hot Standby
Access Point by Using CLI

When you set up the standby access point, you must enter the MAC address of
the access point that the standby unit monitors. Record the MAC address of the
monitored access point before you configure the standby access point.

The standby access point also must duplicate several key settings on the
monitored access point. These settings are:

Primary SSID (as well as additional SSIDs configured on the monitored

access point)

Default IP Subnet Mask
Default Gateway
Data rates
WEP settings
Authentication types and authentication servers

Check the monitored access point and record these settings before you set up the
standby access point.

Message Description

IAPP Standby is Disabled

The access point is not configured for standby mode.

IAPP - AP is in standby mode

The access point is in standby mode.

IAPP - AP is operating in active mode

The standby access point has taken over for the monitored access point
and is functioning as a repeater access point.

IAPP - AP is operating in repeater mode

The standby access point has taken over for the monitored access point
and is functioning as a repeater access point.

Standby status: Initializing

The standby access point is initializing link tests with the monitored
access point.

Standby status: Takeover

The standby access point is operating in standby mode and is running link
tests to the monitored access point.

Standby status: Stopped

Standby mode has been stopped by a configuration command.

Standby status: Ethernet Linktest Failed

An Ethernet link test failed from the standby access point to the
monitored access point.

Standby status: Radio Linktest Failed

A radio link test failed from the standby access point to the monitored
access point.

Standby status: Standby Error

An undefined error occurred.

Standby State: Init

The standby access point is initializing link tests with the monitored
access point.

Standby State: Running

The standby access point is operating in standby mode and is running link
tests to the monitored access point.

Standby State: Stopped

Standby mode has been stopped by a configuration command.

Standby State: Not Running

The access point is not in standby mode.

IMPORTANT

Wireless client devices associated to the standby access point lose their
connections during the hot standby setup process.