Configure the Stratix 5100 WAP Using the Command-Line Interface

Chapter 5

bridge-group 20 spanning-disabled

!

interface Dot11Radio1

/1

no ip address

no ip route-cache

!

encryption vlan 20 key 3 size 128bit 7

741F07447BA1D4382450CB68F37A transmit-key

encryption vlan 20 mode wep mandatory

!

ssid static_wep_ssid

!

speed basic-6.0 9.0 basic-12.0 18.0 basic-24.0

36.0 48.0 54.0

rts threshold 2312

station-role root

bridge-group 1

bridge-group 1 subscriber-loop-control

bridge-group 1 block-unknown-source

no bridge-group 1 source-learning

no bridge-group 1 unicast-flooding

bridge-group 1 spanning-disabled

!

interface Dot11Radio1

/1

.20

encapsulation dot1Q 20

no ip route-cache

bridge-group 20

bridge-group 20 subscriber-loop-control

bridge-group 20 block-unknown-source

no bridge-group 20 source-learning

no bridge-group 20 unicast-flooding

bridge-group 20 spanning-disabled