7000 “C” Frame
1.25” or 2.0” NPTF
Female Pipe Threads
Process Water Inlet
Process Water Outlet
Drive Coolant Inlet
Drive Coolant Outlet
Figure 2.20 – Pipe Flange Detail
Table 2.A – Customer Cooling Requirements for Liquid-to-Liquid Heat Exchangers
Drive
Min. Flow Rate
Max. Pressure
(psig)
Pressure Drop
(kPa)
Temperature ( °C)
Rectifier Voltage
Amps
US
Gpm
L/m
Min.
Max.
18-Pulse
4160
375
33.0
125
435
18
< 0
> 32
430
48.5
183
435
38
< 0
> 32
495
54.5
206
435
43
< 0
> 32
575
22.5
84
435
9
< 0
> 32
657
24.0
90
435
10
< 0
> 32
6600
375
19.5
72
435
7
< 0
> 32
430
21.5
80
435
8
< 0
> 32
495
26.5
100
435
13
< 0
> 32
575
29.0
109
435
15
< 0
> 32
657
37.5
142
435
25
< 0
> 32
PWM
4160
375
19.5
74
435
7
< 0
> 32
430
24.0
90
435
10
< 0
> 32
495
26.5
100
435
13
< 0
> 32
575
33.0
125
435
19
< 0
> 32
6600
375
37.0
139
435
24
< 0
> 32
430
44.5
167
435
34
< 0
> 32
495
48.5
184
435
40
< 0
> 32
575
54.5
206
435
43
< 0
> 32
NOTE:
US Gpm = Gallons per minute (U.S.)
L/m = Liters per minute