background image

Overview of Drive 1-3

7000 “C” Frame

7000L-UM300I-EN-P – June 2013

 Integral pumping panel includes:

Line supply c/w disconnect and fusing
Closed loop coolant system
Iron and chloride free liquid ethyl-glycol / de-ionized water

mixture

Low conductivity coolant (1-2 micro-Siemens / cm

3

)

Isolated from medium voltage
Fully serviceable low voltage compartment isolated from

medium voltage power

Monitors coolant temperature, flow, level, conductivity, and

pressure

Redundant pumping system
Automatic pump change over on pump failure
1/2 turn valves with quick disconnect couplers for pump

replacement when drive is operating

Full drip tray to contain any spilled coolant
Drain and fill pump for convenient filling
Industrial schedule 80 CPVC piping for pump panel, headers

and manifolds (no condensation possibility)

Control hardware for cycling of main / redundant cooling

pumps and Heat exchanger fans

“Plug and play” Power Cage concept

Central location for easy access to all main power

components

Common modular design for rectifier / inverter
Same concept as air cooled drive for front access, easy

component replacement, and no special tools

5-10 minutes to replace main power devices
No need to remove any cooling lines for device replacement
Reduced manufacturing time for faster delivery and lower

cost


Keyed mechanical interlock

Interlocked with main disconnect means to prevent unsafe

access to medium voltage section