Rockwell Automation 7000L PowerFlex Medium Voltage AC Drive (C Frame) - Classic Control User Manual

Page 140

Advertising
background image

3-18

Operator Interface

7000L-UM300I-EN-P – June 2013

7000 “C” Frame

Figure 3.15 – Utility Meter

To change the tag attach to a meter, use the [cursor up] and [cursor
down] keys to highlight the desired meter and press the [enter] key.
(If nothing happens then you have not gained the required access to
make changes.) Press the [F8] key in order to gain access and refer
to the section entitled

Enter/Modify an Access Level

.


This will begin the selection process of a tag as described in the
section entitled "Select a Parameter". When you have completed
the selection process, the selected tag will be assigned to the meter
(i.e. V Line). The name of the meter will have been changed to a
default string as shown in Figure 3.16 for meter 2.

Figure 3.16 – Utility Meter V Line

The text consists of 8 characters. This text is displayed on the Top
Level Menu along with the value and units of the tag. Select the
meter that you wish to modify via the [cursor up] and [cursor down]
keys. To modify the text, press the [cursor right] key. (If nothing
happens then you have not gained the required access to make
changes. Press the [F8] key in order to gain access and refer to the
section entitled

Enter/Modify an Access Level

.


The first character position of the string will be in reverse video as
shown in Figure 3.17. Refer to the section entitled "Edit Text".

Advertising