Component Definition and Maintenance 6-71

7000 “C” Frame

7000L-UM300I-EN-P – June 2013

Thermostatic Valve Replacement


Drive must be shut down while replacing the thermostatic valve.

1. Open valve 10 and drain all coolant before replacing the

thermostatic valve.

2. Note three flanges A, B and C on thermostatic valve. If you

cannot see the marks A, B and C on thermostatic valve, you
should mark three flanges. This is very important to put the
thermostatic valve in correct position. The mark C flange will be
in upper direction, and mark B flange will be in the bottom
direction.

3. First unbolt flange A and B. Unbolt flange C, which is in upper

direction, at the end.

To Heat Exchanger

TV1-C

Thermostatic Valve Housing

TV1-B

TV1-A

V10


Figure 6.57 – Thermostatic Valve Replacement