Tachometer specifications – Rockwell Automation 7000L PowerFlex Medium Voltage AC Drive (C Frame) - Classic Control User Manual

Page 541

Advertising
background image

Catalog Number Explanation – Drive Selection A-5

7000 “C” Frame

7000L-UM300I-EN-P – June 2013

Tachometer Specifications

Avtron : 685 Magneto Resistive

ELECTRICAL

Input Operating Power

Volts (V+)

11.5 VDC to 15.5 VDC

Current

120 mA no load, per output. As loads are added, required current increases.
See following examples for added loads.
Cable impedance
switching examples

320 mA @ 0.05 µF, 15 VDC, 72 kHz differential

15 mA @ 0.05 µF, 12 VDC, 12 kHz, Single ended

Output Example

28 mA for Quadrature output into

1 KΩ, 15 VDC

Alarm Example

+V (OUT) for Alarm 50 mA max.

Electrical Outputs

Outputs

Square wave from 4428 differential line driver with transient protection

Volts, High

(+V) – 1.8 min. (0.05 µF, 15 VDC, 72 kHz,

differential, +V (OUT) @ 50 mA

(+V) – 0.6 max. (0.0 µF, no load)

Note: Does not include cable IR drop.

Volts, Low

0.12 typical, 0.5 max.

Current

1.5 amps peak, 30 mA average typical

Incremental Channel

Quadrature square wave, phase A leads phase B for
CW rotation as viewed from anti-drive end of the motor
(tach mounting end)

Duty Cycle

50% ±5% (average)

Transition Separation 25% ±5% (average)

Resolution

Up to 1200 PPR (see resolution table in the description
section)

Marker Channel

Once per revolution. Pulse width approximately 1/3 of
base PPR period

Alarm Output

Refer to Engineering Note 30.

+V (OUT)

This is a convenience output, internally jumpered to +V
operating voltage. It is intended for alarm circuits like
solid state relays that can be referenced to +V.

Alarm

Open collector, sink 100 mA max., withstand 50V max.
referenced to common. Output goes low on alarm.

MECHANICAL

Speed Range

0-4500 RPM for base PPR of 480
0-4200 RPM for base PPR of 512
0-3600 RPM for base PPR of 600

Weight

6.4 kg (14 lbs)

ENVIRONMENTAL

Operating Temperature

-20°C to 71°C

Dust and Water

A standard M685 pulse generator is shipped with a universal breather/drain to
equalize pressure if the M685 is exposed to temperature cycles and provide a drain
for condensate. The labyrinth design limits the entry of dust to normally satisfactory
levels, and water spray in any direction has no harmful effect. In environments with
stable temperatures, the breather may be replaced with a ¼” pipe plug – making the
pulse generator water-tight and dust-tight.

Features and Specifications subject to changes without notice.

Advertising