Chapter 11

Checking the Hardware

11-6

If you

have a:

If it is not:

It should be:

Check the LED

labeled:

1

MEM ERR will be on at initial power up until memory is cleared or downloaded.

2

These LEDs light after INTERCHANGE software has been loaded.

MicroVAX

Information

Processor

module

PASS/FAIL

GREEN

cycle power by turning off the power from the power supply and then

turning it back on.

make sure the module is seated properly Ċ see appendix A.

ENET CH A

Flashing GREEN (If

connected and

communicating on the

Ethernet network)

make sure the connection to the Ethernet network is secure.

PROCESSOR

OFF

2

BACKPLANE

OFF

2

ENET CH B

OFF

ERROR

OFF

cycle power by turning off the power from the power supply and then

turning it back on.

make sure the module is seated properly Ċ see appendix A.

it will blink the error code. Call support services.

BATTERY LOW

OFF

make sure the battery is inserted correctly in the battery holder.

KA module PASS/FAIL

GREEN

make sure you turn on the power to the power supply.

cycle power by turning off the power from the power supply and then

turn it back on.

MEM ERR

1

OFF

make sure the memory module is connected properly Ċ see appendix A.

CH 1

Flashing GREEN

(if connected)

make sure the connection is secure.

CH 2

Flashing GREEN (if

configured as DH+ link)

CH 3

Flashing GREEN (if

configured as DH+ link)

OSI

Interface

Module

PASS/FAIL

GREEN

cycle power by turning off the power from the power supply and then

turning it back on.

make sure you turn on the power to the power supply.

make sure the module is seated properly Ċ see appendix A.

if cycling power doesn't work, replace the OSI Interface module.

MODE

GREEN

download the program image using AĆB MAP Station Manager.

ACTIVITY

Flashing GREEN (If MAP interface is passing a message.)

MEM ERR

OFF

cycle power by turning off the power from the power supply and then

turning it back on.

make sure you turn on the power to the power supply.

if cycling power doesn't work, replace the OSI Interface module.

BATT LOW

OFF

make sure the battery is inserted correctly in the battery holder.

the lithium battery is weak and should be replaced.

COMM STATUS

GREEN

if the LED is OFF, check 802.4 cable connections. Or check slot time.

if the LED is flashing RED, reset the module through the RSĆ232 local

interface or through a power cycle.

if the LED is RED, reset the module through the RSĆ232 local

interface or through a power cycle.

if resetting the module doesn't work, contact your local AĆB sales

office.

Advertising